- For sea level applications
- Voltage rating: 20 KVDC
- Cable: RG 213/U or RG8/U. For RG 214/U or RG 9/U order connector P/N 167-3516-1
- Braid termination: Crimp
- Max. operating current: (RMS) 20 amps
- Insulation resistance: 106 megohms
- Mating connector: All series 521 receptacles
- Bulk cable ordering & specifications
* This plug is equivalent to the Kings Electronics' plug, P/N 1765-1.
P/N 167-4534

PDF

- For reduced pressure applications
- Voltage rating: 20 KVDC
- Cable: RG 213/U. For RG 214/U cable, order P/N 167-4534-1
- Braid termination: Crimp
- Max. operating current: (RMS) 20 amps
- Insulation resistance: 106 megohms
- Mating connector: All series 521 receptacles
- Bulk cable ordering & specifications


Receptacles (male)

P/N 167-3517

PDF

- 20 KVDC rated
- Pressure: Sealed for 15 psi differential pressure. Max. Leakage: 1 X 10 -6 cc/sec. He.
- Mounting: Front mount. See mounting note
- Mating connector: Mates all series 521 plug cable assemblies
* This receptacle is equivalent to Kings Electronics' P/N 1764-1


Cable Assemblies

P/N 167-3638

PDF

- Double-ended 20 KVDC cable assembly for sea level operation
- Crimp braid termination
- Uses RG213/U cable (shown). Note: For RG 214/U cable, please specify when placing cable assembly order
- 100% voltage test: 28 KVDC @ ambient temperature and pressure
- Mates series 521 Panel connector P/N 167-3517

P/N 167-4450

PDF

- Single-ended 20 KVDC cable assembly for sea level operation
- Crimp braid termination and pigtailed
- Uses RG213/U cable (shown). Note: For RG214/U cable, please specify when ordering cable assembly
- 100% voltage test: 28 KVDC @ ambient temperature and pressure.
- Mates series 521 panel connector P/N 167-3517

P/N 167-4569

PDF

- Double-ended 20 KVDC for reduced pressure operation
- Crimp braid termination
- Uses RG213/U cable (shown). Note: For RG214/U cable, please specify when ordering cable assembly
- Mates series 521 panel connector P/N 167-3517
- 100% voltage test: 41 KVDC @ 70,000 ft. (simulated) & ambient temp.

P/N 167-4596

PDF

- Single-ended 20 KVDC cable assembly for reduced pressure operation
- Crimp braid termination and pigtailed
- Uses RG213/U cable (shown). Note: For RG 214/U cable, please specify when ordering cable assembly.
- Mates series 521 panel connector P/N 167-3517
- 100% voltage test: 41 KVDC @ 70,000 ft. (simulated) & ambient temp.